bugGNU FreeIPMI - Bugs: bug #8718, sensors not interpreting sensor ID...

 
 

bug #8718: sensors not interpreting sensor ID 42 correctly

Submitter:  Joseph Ruscio <jruscio>
Submitted:  Wed 28 Apr 2004 04:54:37 AM UTC
   
 
Category:  sensors Severity:  3 - Normal
Priority:  5 - Normal Item Group:  Improper Behaviour
Status:  Fixed Privacy:  Public
Assigned to:  ab Open/Closed:  Closed
Operating System:  None
* Mandatory Fields

Add a New Comment Rich Markup
   

Thu 02 Sep 2004 08:27:51 AM UTC, comment #1: 

Status interpretation code now solely relies on BMC's report. Old additional buggy code removed.

Anand Babu Periasamy <ab>
Group administrator
Wed 28 Apr 2004 04:54:37 AM UTC, original submission:  

I have observed an incorrect output on sensor 42 when the temperature approaches a high range. The first output is when the temperature is 29 degrees and is as expected. The second output is for a temperature reading of 28 degrees. This reading results in an erroneous status of ALERT.

[jruscio@cdc freeipmi_ft]$ sensors -v -s 42
Record ID: 42
Sensor type: Proc Bd Amb FanB (OEM Reserved)
Sensor number: #85
Event/Reading type code: 01h
Lower non-recoverable threshold: 0.00 Degrees C
Upper non-recoverable threshold: 0.00 Degrees C
Lower Critical threshold: 0.00 Degrees C
Upper Critical threshold: 0.00 Degrees C
Lower non-critical threshold: 0.00 Degrees C
Upper non-critical threshold: 30.00 Degrees C
Sensor min. reading: -128.00 Degrees C
Sensor max. reading: 127.00 Degrees C
Normal min.: 10.00 Degrees C
Nominal reading: 25.00 Degrees C
Normal max: 29.00 Degrees C
Sensor reading: 29.00 Degrees C
Sensor status: OK

[jruscio@cdc freeipmi_ft]$ sensors -v -s 42
Record ID: 42
Sensor type: Proc Bd Amb FanB (OEM Reserved)
Sensor number: #85
Event/Reading type code: 01h
Lower non-recoverable threshold: 0.00 Degrees C
Upper non-recoverable threshold: 0.00 Degrees C
Lower Critical threshold: 0.00 Degrees C
Upper Critical threshold: 0.00 Degrees C
Lower non-critical threshold: 0.00 Degrees C
Upper non-critical threshold: 30.00 Degrees C
Sensor min. reading: -128.00 Degrees C
Sensor max. reading: 127.00 Degrees C
Normal min.: 10.00 Degrees C
Nominal reading: 25.00 Degrees C
Normal max: 29.00 Degrees C
Sensor reading: 28.00 Degrees C
Sensor status: at or above (>=) upper non-critical threshold
Sensor status: ALERT


Joseph Ruscio <jruscio>

 

(Note: upload size limit is set to 16384 kB, after insertion of the required escape characters.)

Attach Files:
   
   
Comment:
   

No files currently attached

 

Depends on the following items: None found

Items that depend on this one: None found

 

CC list is empty

 

There are 0 votes so far. Votes easily highlight which items people would like to see resolved in priority, independently of the priority of the item set by tracker managers.

Only logged-in users can vote.

 

Follow 3 latest changes.

Date Changed by Updated Field Previous Value => Replaced by
2004-09-02 ab StatusNone Fixed
    Assigned toNone ab
    Open/ClosedOpen Closed

Back to the top

Powered by Savane 3.13-cf05.
Corresponding source code