helpAVR In-System Programmer - Support: sr #103567, Have --rd_fuses output all...

 
 

sr #103567: Have --rd_fuses output all calibration bytes

Submitted by:  None
Submitted on:  Sun 14 Nov 2004 03:24:44 PM UTC  
 
Category: NonePriority: 5 - Normal
Severity: 2 - MinorStatus: None
Privacy: PublicAssigned to: None
Originator Email: -unavailable-Open/Closed: Open
Operating System: None

Add a New Comment (Rich MarkupRich Markup):
   

You are not logged in

Please log in, so followups can be emailed to you.

 

Thu 10 Mar 2005 11:44:50 AM UTC, comment #1:

See patch #3819 for solving problem.

Anatoly Sokolov <aesok>
Sun 14 Nov 2004 03:24:44 PM UTC, original submission:

uisp-20040311 --rd_fuses only outputs a device's first, (lowest frequency?) internal clock calibration byte. Could it also sense and output the calibration bytes for a device's other internal clock frequencies?

Thanks for looking into this and thanks for the excellent program!

-John Firestone

From the ATtiny26 data sheet:

The ATtiny26 stores four different calibration values for the internal RC Oscillator. These bytes resides in the signature row high byte of the addresses 0x0000, 0x0001, 0x0002, and 0x0003 for 1, 2, 4, and 8 MHz respectively....

Anonymous

 

(Note: upload size limit is set to 16384 kB, after insertion of the required escape characters.)

Attach File(s):
   
   
Comment:
   

No files currently attached

 

Depends on the following items: None found

Items that depend on this one: None found

 

CC list is empty

 

Do you think this task is very important?
If so, you can click here to add your encouragement to it.
This task has 0 encouragements so far.

Only logged-in users can vote.

 

Please enter the title of George Orwell's famous dystopian book (it's a date):

 

 

No Changes Have Been Made to This Item

Back to the top


Powered by Savane 3.1-cleanup