bugFetch Configuration - Bugs: bug #24705, Serious problems with ProCurve...

 
 

bug #24705: Serious problems with ProCurve module

Submitted by:  Jason Antman <jantman>
Submitted on:  Thu 30 Oct 2008 11:26:15 PM UTC  
 
Category: NoneSeverity: 3 - Normal
Item Group: NoneStatus: Need Info
Privacy: PublicAssigned to: Everton da Silva Marques <evertonm>
Open/Closed: Open

Add a New Comment(Rich Markup)
   

You are not logged in

Please log in, so followups can be emailed to you.

 

Thu 05 Feb 2009 01:06:56 PM UTC, comment #3:

As far as I know, the issue is still present. At least 0.17 still does nothing with my 2424M.

I'm not a perl guy, and am quite busy this week, but I'm plodding along at making some changes to the module, testing, and hopefully creating a patch.

Jason Antman <jantman>
Wed 04 Feb 2009 10:42:22 AM UTC, comment #2:

Jason,

Do you think this bug can be closed?

Thanks,
Everton

Everton da Silva Marques <evertonm>
Project AdministratorIn charge of this item.
Fri 31 Oct 2008 12:04:32 PM UTC, comment #1:

I can't help directly since I don't have access to
ProCurve devices.

Are you able to create a patch to address the
issues (1) and (2) ?

For issue (3), if the switch does not provide a command
for disabling the pager, maybe you can work-around the
pager by using the method expect_enable_prompt_paging()
available in the DmSwitch.pm module:

($prematch, $match) = $self->expect_enable_prompt_paging($t, $prompt, '--More-- ');
if (!defined($prematch)) {
$self->log_error("could not find end of configuration");
return 1;
}

Everton

Everton da Silva Marques <evertonm>
Project AdministratorIn charge of this item.
Thu 30 Oct 2008 11:26:15 PM UTC, original submission:

There seem to be serious issues with the ProCurve module. I don't know what model/OS version it was written for, but I'm running a 2424M (J4093A) with firmware C.09.30 (latest version).

1) After logging in, you're dumped to a menu. To get the command line, you need to send "5" (selection for Diagnostics) and then "4" (selection for Command Line).
2) The script is attempting to send an enable password, but privilege levels in the ProCurve firmware are controlled by the original login password, not an enable password.
3) I can't figure out a way to just dump the whole config - by default, the switch pages it through more.

Jason Antman <jantman>

 

(Note: upload size limit is set to 16384 kB, after insertion of the required escape characters.)

Attach File(s):
   
   
Comment:
   

No files currently attached

 

Depends on the following items: None found

Items that depend on this one: None found

 

Carbon-Copy List
  • -unavailable- added by evertonm (Posted a comment)
  • -unavailable- added by jantman (Submitted the item)
  • -unavailable- added by jantman
  •  

    Do you think this task is very important?
    If so, you can click here to add your encouragement to it.
    This task has 0 encouragements so far.

    Only logged-in users can vote.

     

    Please enter the title of George Orwell's famous dystopian book (it's a date):

     

     

    Follow 3 latest changes.

    Date Changed By Updated Field Previous Value => Replaced By
    Wed 04 Feb 2009 10:42:22 AM UTCevertonmStatusNone=>Need Info
      Assigned toNone=>evertonm
    Thu 30 Oct 2008 11:26:15 PM UTCjantmanCarbon-Copy-=>Added -unavailable-

    Back to the top


    Powered by Savane 3.1-cleanup1