bugDataExplorer - Bugs: bug #62993, steven.colin.martin@gmail.com

 
 

bug #62993: steven.colin.martin@gmail.com

Submitter:  Steven Martin <marto>
Submitted:  Wed 31 Aug 2022 12:00:35 PM UTC
   
 
Category:  None Severity:  3 - Normal
Item Group:  None Status:  Fixed
Privacy:  Public Assigned to:  brueg
Open/Closed:  Closed
* Mandatory Fields

Add a New Comment Rich Markup
   

Fri 13 Jan 2023 03:25:43 PM UTC, comment #5: 

No reaction anymore, close bug report

Winfried Brügmann <brueg>
Group administrator
Tue 06 Sep 2022 04:28:14 PM UTC, comment #4: 

Diving into this problem I found it is device specific. So I fixed it for the iCharger devices. Cell voltage will be get displayed now always with 3 decimal digits as it was initial designed.
Update will be delivered next release.

Winfried Brügmann <brueg>
Group administrator
Sun 04 Sep 2022 05:34:24 PM UTC, comment #3: 

Sorry Steven for the delay,

I already wrote how to do it "So if you want all cell voltages get displayed and exported with 3 decimal digits (0.000) just specify using context menu one of the cell voltages format 0.000 instead of automatic.Do not forget to save graphics template, if done."

For further help check out users guide page 29, "The Curve Selector Context Menu" or while running DataExplorer select the question mark in tools bar, select Curve Selector, this displaying "The Curve Selector Context Menu",  check for "Axis Number Format"

with kind regards, Winfried

Winfried Brügmann <brueg>
Group administrator
Wed 31 Aug 2022 11:52:43 PM UTC, comment #2: 

Thanks for work around. Dumb question how do I get to the context menu to specify the format?

Steven Martin <marto>
Wed 31 Aug 2022 01:34:11 PM UTC, comment #1: 

Steven, the problem is, that all other cell voltages are using format 0.000 and only the cell 1 use the auto format. I will check out this. Table view should follow this as well.

So if you want all cell voltages get displayed and exported with 3 decimal digits (0.000) just specify using context menu one of the cell voltages format 0.000 instead of automatic.Do not forget to save graphics template, if done.

Please refer to attached CSV file.

thanks, Winfried

(file #53645)

Winfried Brügmann <brueg>
Group administrator
Wed 31 Aug 2022 12:00:35 PM UTC, original submission:  

When exporting CSV, Cell 1 is rounded to one decimal place.

Plots fine in DataExplorer only appears corrupted when exported.

Steven Martin <marto>

 

(Note: upload size limit is set to 16384 kB, after insertion of the required escape characters.)

Attach Files:
   
   
Comment:
   

Attached Files
file #53643:  2022-08-31_5_Discharge.csv added by marto (206KiB - application/vnd.ms-excel)
file #53644:  12_13.osd added by marto (96KiB - application/octet-stream)

 

Depends on the following items: None found

Items that depend on this one: None found

 

Carbon-Copy List
  • -email is unavailable- added by brueg (Updated the item)
  • -email is unavailable- added by marto (Submitted the item)
  •  

    There are 0 votes so far. Votes easily highlight which items people would like to see resolved in priority, independently of the priority of the item set by tracker managers.

    Only logged-in users can vote.

     

    Follow 7 latest changes.

    Date Changed by Updated Field Previous Value => Replaced by
    2023-01-13 brueg Open/ClosedOpen Closed
    2022-09-06 brueg StatusConfirmed Fixed
    2022-08-31 brueg Attached File- Added 2022-08-31_5_Discharge_display_format_changed.csv, #53645
        StatusNone Confirmed
        Assigned toNone brueg
    2022-08-31 marto Attached File- Added 2022-08-31_5_Discharge.csv, #53643
        Attached File- Added 12_13.osd, #53644

    Back to the top

    Powered by Savane 3.13-02a9.
    Corresponding source code